Leave a Message
Leave a Message

Please fill out the form below and we will get back to you as soon as possible.

Laboratory Equipment

Labware

Autoclaves

Autoclaves

Labmate Class B type Tabletop Autoclave is an easy to use front loading microprocessor controlled. Equipped with features like automatic shut off preventing overheating of chamber, auto exhaustion of cool air and auto protection against raised temperature and pressure. Available in 18 L to 80 L capacity.



Labmate Class N type Tabletop Autoclave is an easy to use front loading microprocessor controlled, equipped with a printer. Equipped with features like automatic shut off preventing overheating of chamber, auto exhaustion of cool air and auto protection against raised temperature and pressure. Available in 24 L to 80 L capacity.



Labmate Class S Tabletop Autoclave built-in open type water tank. They are commonly used in Medical Healthcare Institution or Research and development to make the sterilization for wrapped or unwrapped instruments.



Labmate Glass bead sterilizer made of stainless steel which operating temperature is 100-300°C. It is commonly used to sterilize surgical instruments like tweezer, scalpels, needles, forceps, inoculation loop. Its small in size can be placed Laminar Air Flow



Labmate Horizontal Autoclave is an easy to use front loading microprocessor controlled. With a maximum working temperature of 134 °C it effectively sterilizes media, liquids and waste to be discarded. Equipped with safety features like automatic shutoff preventing overload of current, auto protection against raised temperature and pressure making a reliable and user friendly device.



Labmate Low Temperature Plasma Autoclave operates with three kinds of sterilization method Plasma, Plasma H2O2 and Ethylene Oxide Gas and works in the temperature range of (-)10 – 55 °C. The equipment comes with an advanced digital time display and up to 225 L capacity. The instrument is a safe and reliable making it suitable for usage in research laboratories.



Labmate Portable Autoclave are made of Stainless steel has a working temperature of 126 ℃ are designed for general purpose sterilization jobs at dental clinics, nursing homes and hospitals etc. The standard models of these systems are available from 18 to 30 liters of capacities. Each unit constructed with heavy gauge aluminum or stainless steel material (optional). The chamber generates steam pressure 0.14 to 0.16 Mpa under working temperature 126 °C. Each system is tested on certain parameters of successful sterilization ensuring safe operation always.



Labmate Vertical Autoclave is a top loading sterilizer with safe, economic, effective operations. It is equipped with user friendly control panel & has silicon rubber seal to prevent leakage. It can be used for sterilization of glass wares, biological materials culture media etc. in hospitals, clinical laboratories, science colleges and others.



Class B - Tabletop Autoclave LMTA-B100
  • Built-in open-type water tank for easy maintenance
  • LCD display of working status
  • Multiple safety protection devices
  • Automatic door structure
  • Auxiliary program: Preheat and washing
  • Built-in instant steam generator


Product Details

Volume : 18 L
Chamber volume : φ 250 x 350 mm
Working temperature : 144 °C
Working pressure : -0.1 / 0.3 Mpa
Sterilization temperature setting range : 105 ~ 138 °C

Volume : 24 L
Chamber volume : φ 250 x 450 mm
Working temperature : 144 °C
Working pressure : -0.1 / 0.3 Mpa
Sterilization temperature setting range : 105 ~ 138 °C

Volume : 45 L
Chamber volume : φ 316 x 618 mm
Working temperature : 144 °C
Working pressure : -0.1 / 0.3 Mpa
Sterilization temperature setting range : 105 ~ 138 °C

Volume : 60 L
Chamber volume : φ 358 x 595 mm
Working temperature : 144 °C
Working pressure : -0.1 / 0.3 Mpa
Sterilization temperature setting range : 105 ~ 138 °C

Volume : 80 L
Chamber volume : φ 358 x 717 mm
Working temperature : 144 °C
Working pressure : -0.1 / 0.3 Mpa
Sterilization temperature setting range : 105 ~ 138 °C
Class N - Tabletop Autoclave LMTA-A100
  • Automated sterilization controlled by computer
  • Working temperature: 134 ℃
  • 4 - 6 minutes flash sterilization
  • Over heat and over pressure protection
  • Automatic shut off with alarm indication
  • Stainless steel structure


Product Details

Volume : 24 L
Chamber volume : φ 270 x 410 mm
Working temperature : 134 ℃
Working pressure : 0.22 Mpa
Sterilization temperature setting range : 105 ~ 134 ℃

Volume : 20 L
Chamber volume : φ 250 x 420 mm
Working temperature : 134 ℃
Working pressure : 0.22 Mpa
Sterilization temperature setting range : 105 ~ 134 ℃

Volume : 24 L
Chamber volume : φ 250 x 520 mm
Working temperature : 134 ℃
Working pressure : 0.22 Mpa
Sterilization temperature setting range : 105 ~ 134 ℃

Volume : 20 L
Chamber volume : φ 250 x 420 mm
Working temperature : 134 ℃
Working pressure : 0.22 Mpa
Sterilization temperature setting range : 105 ~ 134 ℃

Volume : 24 L
Chamber volume : φ 250 x 520 mm
Working temperature : 134 ℃
Working pressure : 0.22 Mpa
Sterilization temperature setting range : 105 ~ 134 ℃

Volume : 35 L
Chamber volume : φ 300 x 500 mm
Working temperature : 134 ℃
Working pressure : 0.22 Mpa
Sterilization temperature setting range : 105 ~ 134 ℃

Volume : 50 L
Chamber volume : φ 340 x 550 mm
Working temperature : 134 ℃
Working pressure : 0.22 Mpa
Sterilization temperature setting range : 105 ~ 134 ℃

Volume : 24 L
Chamber volume : φ 250 x 450 mm
Working temperature : 144 ℃
Working pressure : -0.1 Mpa
Sterilization temperature setting range : 105 ~ 138 ℃

Volume : 45 L
Chamber volume : φ 316 x 618 mm
Working pressure : -0.1 Mpa
Power : 5.8 kW
Voltage : AC 220 V / 50 Hz

Volume : 80 L
Chamber volume : φ 358 x 717 mm
Working pressure : -0.1 Mpa
Power : 7.4 kW
Voltage : AC 220 V / 50 Hz

Volume : 23 L
Chamber volume : φ 250 x 440 mm
Working temperature : 150 ℃
Working pressure : 0.28 Mpa
Sterilization temperature setting range : 105 ~ 134 ℃
Class S Tabletop Autoclave LMLT-A100
  • LCD Display
  • Multiple security protective devices
  • Built-in open type water tank
  • Working Temperature: 144 °
  • Water level sensor
  • Preheat and washing Auxiliary program
  • Built-in instant steam generator


Product Details

Capacity : 24 L
Chamber Size : Φ 250 x 450 mm
Working Temperature : 144 °C
Sterilization Temperature Range : 105 - 138 °C
Power : 2.6 kW

Capacity : 45 L
Chamber Size : Φ 316 x 618 mm
Working Temperature : 144 °C
Sterilization Temperature Range : 105 - 138 °C
Power : 2.6 kW

Capacity : 80 L
Chamber Size : Φ358 x 717 mm
Working Temperature : 144 °C
Sterilization Temperature Range : 105 - 138 °C
Power : 2.6 kW
Glass Bead sterilizer LMGS-A100
  • Material: Stainless Steel
  • Sterilizes in 10 second
  • Reusable glass bead
  • Digital parameter display


Product Details

Weight of Glass Beads : 150 g
Temperature Range : 100 - 300 °C
Temperature Accuracy : ≤ ± 5 °C
Heating Time to Max. Temperature : ≤ 25 min to reach 300 °C
Ambient Temp : 5 °C - 40 °C

Weight of Glass Beads : 300 g
Temperature Range : 100 - 300 °C
Temperature Accuracy : ≤ ± 5 °C
Heating Time to Max. Temperature : ≤ 25 min to reach 300 °C
Ambient Temp : 5 °C - 40 °C
Horizontal Autoclave LMHA-A100
  • Microcomputer control system with LED digital display
  • Semi-automatic Control
  • Over heat and over pressure protection
  • Preset program to sterilize solid body
  • Provide temperature and pressure check interface
  • Automatic alarm indication after shut down.
  • Exhaust steam control
  • Interlock device
  • Safety valve for over pressure exhausting
  • Stores the data from last operation program
  • With print function


Product Details

Volume : 120 L
Chamber volume : 400 x 960 mm
Working temperature : 50 - 134 ℃
Working pressure : 0.217 MPa
Configuration : Semi-automatic Control

Volume : 200 L
Chamber volume : 500 x 1020 mm
Working temperature : 50 - 134 ℃
Working pressure : 0.217 MPa
Configuration : Semi-automatic Control

Volume : 300 L
Chamber volume : 600 x 1050 mm
Working temperature : 50 - 134 ℃
Working pressure : 0.217 MPa
Configuration : Semi-automatic Control

Volume : 150 L
Chamber volume : φ 400 x 1000 mm
Working temperature : 134 ℃
Working pressure : 0.22 MPa
Configuration : Fully Automated

Volume : 200 L
Chamber volume : φ 515 x 1000 mm
Working temperature : 134 ℃
Working pressure : 0.22 MPa
Configuration : Fully Automated

Volume : 280 L
Chamber volume : φ 600 x 1000 mm
Working temperature : 134 ℃
Working pressure : 0.22 MPa
Configuration : Fully Automated

Volume : 400 L
Chamber volume : φ 700 x 1100 mm
Working temperature : 134 ℃
Working pressure : 0.22 MPa
Configuration : Fully Automated

Volume : 500 L
Chamber volume : φ 700 x 1300 mm
Working temperature : 134 ℃
Working pressure : 0.22 MPa
Configuration : Fully Automated

Volume : 150 L
Chamber volume : φ 400 x 1000 mm
Working temperature : 134 ℃
Working pressure : 0.22 MPa
Configuration : Fully Automated

Volume : 200 L
Chamber volume : φ 515 x 1000 mm
Working temperature : 134 ℃
Working pressure : 0.22 MPa
Configuration : Fully Automated

Volume : 280 L
Chamber volume : φ 600 x 1000 mm
Working temperature : 134 ℃
Working pressure : 0.22 MPa
Configuration : Fully Automated

Volume : 150 L
Chamber volume : φ 400 x 1000 mm
Working temperature : 134 ℃
Working pressure : 0.22 MPa
Configuration : Fully Automated

Volume : 200 L
Chamber volume : φ 515 x 1000 mm
Working temperature : 134 ℃
Working pressure : 0.22 MPa
Configuration : Fully Automated

Volume : 280 L
Chamber volume : φ 600 x 1000 mm
Working temperature : 134 ℃
Working pressure : 0.22 MPa
Configuration : Fully Automated

Volume : 400 L
Chamber volume : φ 700 x 1100 mm
Working temperature : 134 ℃
Working pressure : 0.22 MPa
Configuration : Fully Automated

Volume : 150 L
Chamber volume : φ 400 x 1000 mm
Working temperature : 134 ℃
Working pressure : 0.22 MPa
Configuration : Fully Automated

Volume : 200 L
Chamber volume : φ 515 x 1000 mm
Working temperature : 134 ℃
Working pressure : 0.22 MPa
Configuration : Fully Automated

Volume : 280 L
Chamber volume : φ 600 x 1000 mm
Working temperature : 134 ℃
Working pressure : 0.22 MPa
Configuration : Fully Automated
Low Temperature Plasma Autoclave LMLA-A100
  • Adjustable air flow speed
  • Multi - Point particle monitoring
  • Infrared sensor for automatic sterilization
  • Touch control panel with remote control
  • Accurate time display
  • Multiple sensor for inspect air quality, temperature and Humidity


Product Details

Applicable Room : < 100 m3
Type : Free Standing
Circulating Air : > 800 m3/ h
Working Temperature : (-)10 - 40 °C
Working Atmosphere Pressure : 86 ~ 106 kPa

Applicable Room : < 100 m3
Type : Mobile
Circulating Air : > 800 m3/ h
Working Temperature : (-)10 - 40 °C
Working Atmosphere Pressure : 86 ~ 106 kPa

Applicable Room : < 100 m3
Type : Wall Mounted
Circulating Air : > 800 m3/ h
Working Temperature : (-)10 - 40 °C
Working Atmosphere Pressure : 86 ~ 106 kPa

Applicable Room : < 100 m3
Type : Ceiling Mounted
Circulating Air : > 800 m3/ h
Working Temperature : (-)10 - 40 °C
Working Atmosphere Pressure : 86 ~ 106 kPa

Capacity : 64 L
Chamber Diameter : 650 x 380 x 260 mm
Sterilization Method : Hydrogen Peroxide Gas Sterilization
Working Temperature : 50 ± 5 °C
Power : 3.5 kW

Capacity : 135 L
Chamber Diameter : 750 x 450 x 400 mm
Sterilization Method : Hydrogen Peroxide Gas Sterilization
Working Temperature : 50 ± 5 °C
Power : 3.8 kW

Capacity : 225 L
Chamber Diameter : 1250 x 450 x 400 mm
Sterilization Method : Hydrogen Peroxide Gas Sterilization
Working Temperature : 50 ± 5 °C
Power : 4.7 kW

Capacity : 135 L
Chamber Diameter : 750 x 450 x 400 mm
Sterilization Method : Ethylene Oxide Sterilization
High Temperature : 55 °C
Low Temperature : 37 °C

Capacity : 225 L
Chamber Diameter : 1250 x 450 x 400 mm
Sterilization Method : Ethylene Oxide Sterilization
High Temperature : 55 °C
Low Temperature : 37 °C
Portable Autoclave LMPA-A100
  • Working Temperature: 126 ℃
  • Stainless steel structure
  • Dual scale indicating pressure gauge
  • Electric or LPG heated


Product Details

Volume : 18 L
Chamber volume : Φ 280 x 260 mm
Working temperature : 126 °C
Heating Mode : Electric / LPG Heated
Working pressure : 0.14 ~ 0.16 Mpa

Volume : 24 L
Chamber volume : Φ 280 x 390 mm
Working temperature : 126 °C
Heating Mode : Electric / LPG Heated
Working pressure : 0.14 ~ 0.16 Mpa

Volume : 18 L
Chamber volume : Φ 280 x 260 mm
Working temperature : 126 °C
Heating Mode : Electric heated
Working pressure : 0.14 ~ 0.16 Mpa

Volume : 24 L
Chamber volume : Φ 280 x 390 mm
Working temperature : 126 °C
Heating Mode : Electric heated
Working pressure : 0.14 ~ 0.16 Mpa

Volume : 18 L
Chamber volume : Φ 280 x 260 mm
Working temperature : 126 °C
Heating Mode : Electric heated
Working pressure : 0.14 ~ 0.16 Mpa

Volume : 24 L
Chamber volume : Φ 280 x 390 mm
Working temperature : 126 °C
Heating Mode : Electric heated
Working pressure : 0.14 ~ 0.16 Mpa

Volume : 18 L
Chamber volume : 280 x 395 mm
Working pressure : 0.142 Mpa
Sterilization temperature setting range : 50 - 126 ℃
Time : 0 – 999 min

Volume : 24 L
Chamber volume : 280 x 495 mm
Working pressure : 0.142 Mpa
Sterilization temperature setting range : 50 - 126 ℃
Time : 0 – 999 min

Volume : 30 L
Chamber volume : 280 x 585 mm
Working pressure : 0.142 Mpa
Sterilization temperature setting range : 50 - 126 ℃
Time : 0 – 999 min
Vertical Autoclave LMVT-A100
  • Fully stainless steel structure
  • LED display of working status with touch type key
  • Alarm indication with auto shut down
  • Auto discharge of cool air and steam
  • Two stainless steel sterilizing basket


Product Details

Volume : 35 L
Chamber volume : φ 318 x 450 mm
Working temperature : 134 °C
Working pressure : 0.22 MPa
Max working pressure : 0.23 MPa

Volume : 50 L
Chamber volume : φ 340 x 550 mm
Working temperature : 134 °C
Working pressure : 0.22 MPa
Max working pressure : 0.23 MPa

Volume : 75 L
Chamber volume : φ 400 x 600 mm
Working temperature : 134 °C
Working pressure : 0.22 MPa
Max working pressure : 0.23 MPa

Volume : 100 L
Chamber volume : φ 440 x 650 mm
Working temperature : 134 °C
Working pressure : 0.22 MPa
Max working pressure : 0.23 MPa

Volume : 35 L
Chamber volume : φ 318 x 450 mm
Working temperature : 134 °C
Working pressure : 0.22 MPa
Max working pressure : 0.23 MPa

Volume : 50 L
Chamber volume : φ 340 x 550 mm
Working temperature : 134 °C
Working pressure : 0.22 MPa
Max working pressure : 0.23 MPa

Volume : 75 L
Chamber volume : φ 400 x 600 mm
Working temperature : 134 °C
Working pressure : 0.22 MPa
Max working pressure : 0.23 MPa

Volume : 100 L
Chamber volume : φ 440 x 650 mm
Working temperature : 134 °C
Working pressure : 0.22 MPa
Max working pressure : 0.23 MPa

Volume : 35 L
Chamber volume : φ 318 x 450 mm
Working temperature : 134 °C
Working pressure : 0.22 MPa
Max working pressure : 0.23 MPa

Volume : 50 L
Chamber volume : φ 340 x 550 mm
Working temperature : 134 °C
Working pressure : 0.22 MPa
Max working pressure : 0.23 MPa

Volume : 75 L
Chamber volume : φ 400 x 600 mm
Working temperature : 134 °C
Working pressure : 0.22 MPa
Max working pressure : 0.23 MPa

Volume : 100 L
Chamber volume : φ 440 x 650 mm
Working temperature : 134 °C
Working pressure : 0.22 MPa
Max working pressure : 0.23 MPa

Configuration : Basic Configuration
Volume : 30 L
Chamber volume : 370 x 320 mm
Working pressure : 0.217 MPa
Sterilization temperature setting range : 50 - 134 °C

Configuration : Basic Configuration
Volume : 50 L
Chamber volume : 370 x 500 mm
Working pressure : 0.217 MPa
Sterilization temperature setting range : 50 - 134 °C

Configuration : Basic Configuration
Volume : 75 L
Chamber volume : 370 x 690 mm
Working pressure : 0.217 MPa
Sterilization temperature setting range : 50 - 134 °C

Configuration : Auto exhaust
Volume : 30 L
Chamber volume : 370 x 320 mm
Working pressure : 0.217 MPa
Sterilization temperature setting range : 50 - 134 °C

Configuration : Auto exhaust
Volume : 50 L
Chamber volume : 370 x 500 mm
Working pressure : 0.217 MPa
Sterilization temperature setting range : 50 - 134 °C

Configuration : Auto exhaust
Volume : 75 L
Chamber volume : 370 x 690 mm
Working pressure : 0.217 MPa
Sterilization temperature setting range : 50 - 134 °C

Configuration : Drying
Volume : 30 L
Chamber volume : 370 x 320 mm
Working pressure : 0.217 MPa
Sterilization temperature setting range : 50 - 134 °C

Configuration : Drying
Volume : 50 L
Chamber volume : 370 x 500 mm
Working pressure : 0.217 MPa
Sterilization temperature setting range : 50 - 134 °C

Configuration : Drying
Volume : 75 L
Chamber volume : 370 x 690 mm
Working pressure : 0.217 MPa
Sterilization temperature setting range : 50 - 134 °C

Configuration : Automatic Control
Volume : 30 L
Chamber volume : 350 x 330 mm
Working temperature : 50 - 126 °C
Working pressure : 0.142 MPa

Configuration : Automatic Control
Volume : 50 L
Chamber volume : 350 x 520 mm
Working temperature : 50 - 126 °C
Working pressure : 0.142 MPa

Configuration : Automatic Control
Volume : 75 L
Chamber volume : 388 x 650 mm
Working temperature : 50 - 126 °C
Working pressure : 0.142 MPa

Configuration : Automatic Control
Volume : 100 L
Chamber volume : 500 x 550 mm
Working temperature : 50 - 134 °C
Working pressure : 0.217 MPa

Configuration : Automatic Control
Volume : 150 L
Chamber volume : 500 x 760 mm
Working temperature : 50 - 134 °C
Working pressure : 0.217 MPa

Configuration : Automatic Control
Volume : 200 L
Chamber volume : 500 x 1000 mm
Working temperature : 50 - 134 °C
Working pressure : 0.217 MPa

Configuration : Basic Configuration
Volume : 40 L
Chamber volume : 370 x 380 mm
Working pressure : 0.217 MPa
Sterilization temperature setting range : 50 - 134 °C

Configuration : Basic Configuration
Volume : 60 L
Chamber volume : 370 x 560 mm
Working pressure : 0.217 MPa
Sterilization temperature setting range : 50 - 134 °C

Configuration : Basic Configuration
Volume : 80 L
Chamber volume : 370 x 750 mm
Working pressure : 0.217 MPa
Sterilization temperature setting range : 50 - 134 °C

Configuration : Steam emission by internal circulation
Volume : 40 L
Chamber volume : 370 x 380 mm
Working pressure : 0.217 MPa
Sterilization temperature setting range : 50 - 134 °C

Configuration : Steam emission by internal circulation
Volume : 60 L
Chamber volume : 370 x 560 mm
Working pressure : 0.217 MPa
Sterilization temperature setting range : 50 - 134 °C

Configuration : Steam emission by internal circulation
Volume : 80 L
Chamber volume : 370 x 750 mm
Working pressure : 0.217 MPa
Sterilization temperature setting range : 50 - 134 °C

Configuration : Drying
Volume : 40 L
Chamber volume : 370 x 380 mm
Working pressure : 0.217 MPa
Sterilization temperature setting range : 50 - 134 °C

Configuration : Drying
Volume : 60 L
Chamber volume : 370 x 560 mm
Working pressure : 0.217 MPa
Sterilization temperature setting range : 50 - 134 °C

Configuration : Drying
Volume : 80 L
Chamber volume : 370 x 750 mm
Working pressure : 0.217 MPa
Sterilization temperature setting range : 50 - 134 °C