Leave a Message
Leave a Message

Please fill out the form below and we will get back to you as soon as possible.

Laboratory Equipment

Labware

Spectrophotometer

Spectrophotometer

Labmate Double beam UV/Visible spectrophotometer offers highly stable optical system ensuring long-term stability. Large screen enables effective display of graphics. Design offer low stray light, low noise and lower laser drift. Auto setting of wavelength and blank facilitates quicker measurement. USB port interface allow easy transfer of data. Highly suitable for research, biochemical and pharmaceuticals laboratories.



Labmate Single beam UV/visible spectrophotometer use in quantitative absorption measurement at UV/visible spectral range. Large LCD display enable real time observation and data storage. Auto setting of wavelength and blank facilitates quicker measurement. It has stable optical system with high quality grating of 1200 lines/mm. It has varied use in academic laboratory experiments and quality control testing.



Labmate Split beam UV/Visible spectrophotometer offers split beam ratio monitoring at UV/Visible range. Large LCD display allows real time observation and data storage. Split beam ensures low laser drift. Microcontroller and high precision AD ensures faster operation. It has significant use in research laboratories for chemistry, physics and biochemistry.



Labmate Visible spectrophotometer is a high quality space saving model. Large LCD display enable real time observation and data storage. Auto setting of wavelength and blank facilitates quicker measurement. It has stable optical system with high quality grating of 1200 lines/mm. It has varied use in academics and quality control aspects.



Double Beam UV/Visible Spectrophotometer LMUD-A100
  • Wavelength range: 190 nm – 1100 nm
  • Spectral bandwidth: 1.0 nm
  • Automatic wavelength setting
  • Replaceable Pre-aligned lamps (Tungsten and Deuterium)
  • High quality electrical and optical system
  • Optical PC scanning software with USB port
  • Low noise and low stray light


Product Details

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 1 nm
Optical System : Double Beam, grating (1200 lines/minute)
Wavelength Accuracy : 0.3 nm
Wavelength Repeatability : 0.1 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 1 nm
Optical System : Double Beam, grating (1200 lines/minute)
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.2 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 1.8 nm
Optical System : Double Beam, grating (1200 lines/minute)
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.1 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 1.8 nm
Optical System : Double Beam, grating (1200 lines/minute)
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.2 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 2 nm
Optical System : Double Beam, grating (1200 lines/minute)
Wavelength Accuracy : 0.3 nm
Wavelength Repeatability : 0.1 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 2 nm
Optical System : Double Beam, grating (1200 lines/minute)
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.2 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 0.5 nm, 1 nm, 2 nm, 4 nm, 5 nm
Optical System : Double Beam, grating (1200 lines/minute)
Wavelength Accuracy : 0.3 nm
Wavelength Repeatability : 0.1 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 0.5 nm, 1 nm, 2 nm, 4 nm, 5 nm
Optical System : Double Beam, grating (1200 lines/minute)
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.2 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 1 nm
Optical System : Double Beam, grating (1200 lines/minute)
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.1 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 1 nm
Optical System : Double Beam, grating (1200 lines/minute)
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.1 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 1 nm
Optical System : Double Beam, grating (1200 lines/minute)
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.1 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 2 nm
Optical System : Double Beam, grating (1200 lines/minute)
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.1 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 2 nm
Optical System : Double Beam, grating (1200 lines/minute)
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.1 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 2 nm
Optical System : Double Beam, grating (1200 lines/minute)
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.1 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 0.5 nm, 1 nm, 2 nm, 4 nm, 5 nm
Optical System : Double Beam, grating (1200 lines/minute)
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.1 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 0.5 nm, 1 nm, 2 nm, 4 nm, 5 nm
Optical System : Double Beam, grating (1200 lines/minute)
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.1 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 0.5 nm, 1 nm, 2 nm, 4 nm, 5 nm
Optical System : Double Beam, grating (1200 lines/minute)
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.1 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 1 nm
Optical System : Double Beam, grating (1200 lines/minute)
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.1 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 1 nm
Optical System : Double Beam, grating (1200 lines/minute)
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.1 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 1 nm
Optical System : Double Beam, grating (1200 lines/minute)
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.1 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 1 nm
Optical System : Double Beam, grating (1200 lines/minute)
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.1 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 2 nm
Optical System : Double Beam, grating (1200 lines/minute)
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.1 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 2 nm
Optical System : Double Beam, grating (1200 lines/minute)
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.1 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 2 nm
Optical System : Double Beam, grating (1200 lines/minute)
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.1 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 2 nm
Optical System : Double Beam, grating (1200 lines/minute)
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.1 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 0.5 nm, 1 nm, 2 nm, 4 nm, 5 nm
Optical System : Double Beam, grating (1200 lines/minute)
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.1 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 0.5 nm, 1 nm, 2 nm, 4 nm, 5 nm
Optical System : Double Beam, grating (1200 lines/minute)
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.1 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 0.5 nm, 1 nm, 2 nm, 4 nm, 5 nm
Optical System : Double Beam, grating (1200 lines/minute)
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.1 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 0.5 nm, 1 nm, 2 nm, 4 nm, 5 nm
Optical System : Double Beam, grating (1200 lines/minute)
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.1 nm
Single Beam UV/Visible Spectrophotometer LMUS-A100
  • Wavelength range: 190 nm – 1020 nm
  • Manual wavelength setting
  • Spectral bandwidth: 2.0 nm
  • Replaceable Pre-aligned lamps (Tungsten and Deuterium)
  • High quality electrical and optical system
  • PC scanning software with USB port
  • Low noise and low stray light


Product Details

Wavelength : 190 nm – 1020 nm
Spectral Bandwidth : 2 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : 2 nm
Wavelength Repeatability : 1 nm

Wavelength : 190 nm – 1020 nm
Spectral Bandwidth : 4 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : 2 nm
Wavelength Repeatability : 1 nm

Wavelength : 195 nm – 1020 nm
Spectral Bandwidth : 5 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : ± 2 nm
Wavelength Repeatability : 1 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 1 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : 0.5 nm
Wavelength Repeatability : 0.2 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 1.8 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : ± 0.5 nm
Wavelength Repeatability : ≤ 0.2 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 1.8 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : 0.3 nm
Wavelength Repeatability : 0.1 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 2 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : ± 0.5 nm
Wavelength Repeatability : ≤ 0.2 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 2 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : ± 0.8 nm
Wavelength Repeatability : ≤ 0.3 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 2 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : 1 nm
Wavelength Repeatability : ≤ 0.5 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 2 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : 1 nm
Wavelength Repeatability : ≤ 0.2 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 2 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : 2 nm
Wavelength Repeatability : 1 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 4 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : ± 1 nm
Wavelength Repeatability : ≤ 0.3 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 4 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : 1 nm
Wavelength Repeatability : ≤ 0.5 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 4 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : 2 nm
Wavelength Repeatability : 1nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 0.5 / 1 / 2 / 4 / 5 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : 0.3 nm
Wavelength Repeatability : 0.1 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 1 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.1 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 2 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.1 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 0.5 / 1 / 2 / 4 / 5 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.1 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 1 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.1 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 1 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.1 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 2 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.1 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 2 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.1 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 0.5 / 1 / 2 / 4 / 5 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.1 nm

Wavelength : 190 nm – 1100 nm
Spectral Bandwidth : 0.5 / 1 / 2 / 4 / 5 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.1 nm
Split Beam UV/Visible Spectrophotometer LMUP-A100
  • Wavelength range: 190 nm -1100 nm
  • Optical system retrains laser drift
  • Spectral bandwidth: 1.0 nm (fixed)
  • High speed microcontroller (MCU), high precision AD
  • Automatic wavelength and blank setting
  • Low noise and low stray light
  • Easy to change Pre-aligned lamps (tungsten and deuterium)
  • Optical PC scanning software with USB port


Product Details

Wavelength : 190 nm - 1100 nm
Spectral Bandwidth : 1.0 nm
Optical System : Split Beam Ratio monitoring, Blazed Holographic grating (1200 lines/minute)
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.2 nm

Wavelength : 190 nm - 1100 nm
Spectral Bandwidth : 1.8 nm
Optical System : Split Beam Ratio monitoring, Blazed Holographic grating (1200 lines/minute)
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.2 nm

Wavelength : 190 nm - 1100 nm
Spectral Bandwidth : 2 nm
Optical System : Split Beam Ratio monitoring, Blazed Holographic grating (1200 lines/minute)
Wavelength Accuracy : ± 0.5 nm
Wavelength Repeatability : ≤ 0.2 nm

Wavelength : 190 nm - 1100 nm
Spectral Bandwidth : 0.5 nm, 1 nm, 2 nm , 4 nm, 5 nm
Optical System : Split Beam Ratio monitoring, Blazed Holographic grating (1200 lines/minute)
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.2 nm
Single Beam Visible Spectrophotometer LMSV-A100
  • Wavelength range: 320 nm – 1020 nm
  • Manual wavelength setting
  • Spectral bandwidth: 4 nm
  • High quality electrical and optical system
  • PC scanning software with USB port
  • Low noise and low stray light


Product Details

Wavelength : 320 nm – 1020 nm
Spectral Bandwidth : 4 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : 2 nm
Wavelength Repeatability : 1 nm

Wavelength : 320 nm – 1100 nm
Spectral Bandwidth : 1.8 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : ± 0.5 nm
Wavelength Repeatability : ≤ 0.2 nm

Wavelength : 320 nm – 1100 nm
Spectral Bandwidth : 2 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : 0.3 nm
Wavelength Repeatability : 0.2 nm

Wavelength : 320 nm – 1100 nm
Spectral Bandwidth : 2 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : ± 0.5 nm
Wavelength Repeatability : ≤ 0.1 nm

Wavelength : 320 nm – 1100 nm
Spectral Bandwidth : 2 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : ± 0.8 nm
Wavelength Repeatability : ≤ 0.3 nm

Wavelength : 320 nm – 1100 nm
Spectral Bandwidth : 4 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : ± 1.0 nm
Wavelength Repeatability : ≤ 0.3 nm

Wavelength : 320 nm – 1100 nm
Spectral Bandwidth : 4 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : 2 nm
Wavelength Repeatability : 1 nm

Wavelength : 360 nm – 1000 nm
Spectral Bandwidth : 4 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : 1 nm
Wavelength Repeatability : ≤ 0.2 nm

Wavelength : 360 nm – 1020 nm
Spectral Bandwidth : 5 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : ± 2 nm
Wavelength Repeatability : 1 nm

Wavelength : 360 nm – 1020 nm
Spectral Bandwidth : 6 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : ± 3 nm
Wavelength Repeatability : 1 nm

Wavelength : 320 nm- 1100 nm
Spectral Bandwidth : 2 nm
Optical System : Split Beam Ratio monitoring, Grating (1200 lines/minute)
Wavelength Accuracy : ± 0.5 nm
Wavelength Repeatability : ≤ 0.2 nm