Visible Spectrophotometer

Single Beam Visible Spectrophotometer LMSV A100
Single Beam Visible Spectrophotometer LMSV A100
  • Wavelength range: 320 nm – 1020 nm
  • Manual wavelength setting
  • Spectral bandwidth: 4 nm
  • High quality electrical and optical system
  • PC scanning software with USB port
  • Low noise and low stray light

Product Details
Single Beam Visible Spectrophotometer LMSV-A100

Wavelength : 320 nm – 1020 nm
Spectral Bandwidth : 4 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : 2 nm
Wavelength Repeatability : 1 nm

Single Beam Visible Spectrophotometer LMSV-A200

Wavelength : 320 nm – 1100 nm
Spectral Bandwidth : 1.8 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : ± 0.5 nm
Wavelength Repeatability : ≤ 0.2 nm

Single Beam Visible Spectrophotometer LMSV-A201

Wavelength : 320 nm – 1100 nm
Spectral Bandwidth : 2 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : 0.3 nm
Wavelength Repeatability : 0.2 nm

Single Beam Visible Spectrophotometer LMSV-A202

Wavelength : 320 nm – 1100 nm
Spectral Bandwidth : 2 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : ± 0.5 nm
Wavelength Repeatability : ≤ 0.1 nm

Single Beam Visible Spectrophotometer LMSV-A203

Wavelength : 320 nm – 1100 nm
Spectral Bandwidth : 2 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : ± 0.8 nm
Wavelength Repeatability : ≤ 0.3 nm

Single Beam Visible Spectrophotometer LMSV-A204

Wavelength : 320 nm – 1100 nm
Spectral Bandwidth : 4 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : ± 1.0 nm
Wavelength Repeatability : ≤ 0.3 nm

Single Beam Visible Spectrophotometer LMSV-A205

Wavelength : 320 nm – 1100 nm
Spectral Bandwidth : 4 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : 2 nm
Wavelength Repeatability : 1 nm

Single Beam Visible Spectrophotometer LMSV-A300

Wavelength : 360 nm – 1000 nm
Spectral Bandwidth : 4 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : 1 nm
Wavelength Repeatability : ≤ 0.2 nm

Single Beam Visible Spectrophotometer LMSV-A301

Wavelength : 360 nm – 1020 nm
Spectral Bandwidth : 5 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : ± 2 nm
Wavelength Repeatability : 1 nm

Single Beam Visible Spectrophotometer LMSV-A302

Wavelength : 360 nm – 1020 nm
Spectral Bandwidth : 6 nm
Optical System : Single Beam, Grating 1200 lines/mm
Wavelength Accuracy : ± 3 nm
Wavelength Repeatability : 1 nm

Split Beam Visible Spectrophotometer LMSV-B100

Wavelength : 320 nm- 1100 nm
Spectral Bandwidth : 2 nm
Optical System : Split Beam Ratio monitoring, Grating (1200 lines/minute)
Wavelength Accuracy : ± 0.5 nm
Wavelength Repeatability : ≤ 0.2 nm