Dual Block Thermal Cycler LMMB-E103 utilizes 8 Peltier heating units to heat up the sample with 4 variations in temperature. It has preprogrammed 11 PCR protocols saved in internal flash memory. The instrument work significantly faster using windows operations system and can monitor the operations via mobile connectivity. Movable heating lid can accommodate 48×0.2 ml+30×0.5ml wells or tube. It can with stand up to ramping rate of 5 °C/s and temperature range of 0 to 100 °C. Installed with capability of analyzing maximum 100cycles and can save 10000 PRC run data. The parameters update and file transfer updates through Wi-Fi, USB, printer can be seen on 8-inches LCD display.

Specifications :
Capacity 48×0.2 ml+30×0.5 ml
Temperature Range 0 to 100 °C
Maximum. Heating Rate 5 °C/s
Maximum. Cooling Rate 4 °C/s
Uniformity ≤ ± 0.2 °C
Accuracy ≤ ± 0.1 °C
Display Resolution 0.1 °C
Temperature Control Block\Tube
Ramping Rate Adjustable 0.1 to 5 °C
Gradient Uniformity ≤ ± 0.2 °C
Gradient Accuracy ≤ ± 0.2 °C
Gradient Temperature. Range 30 to 100 °C
Gradient Spread 1 to 30 °C
Hot Lid Temperature 30 to 110 °C
Hot Lid Height Adjustable Step less Adjustable
No. Of Programs 10000 +(USB FLASH)
Maximum. No. Of Step 30
Maximum. No. Of Cycle 100
Increment/Decrement Time 1 Sec to 600 Sec
Increment/Decrement Temperature 0.1 to 10.0 °C
Pause Function Yes
Auto Data Protection Yes
Holding 4 °C
Print Yes
LAN to computer Yes
LCD 8 inch, 800 x 600 pels, 260,000 colors
Interface USB2.0 , LAN
Dimensions(L×W×H) 390×270×255 mm
Weight 9 kg
Power Consumption 600 W
Power Supply 85 to 264 V AC , 47 to 63 Hz
Features :
  • -  It has 8-inches LCD display which enables the user to change the commands
  • -  Uniform heating with 4 different temperature of the samples is achieved with 8 Peltier heating units with maximum 100 cycles
  • -  It is well built with anodizing technology with aluminum block treatment which makes the durable and corrosion resistant
  • -  Two different PCR programs can be assigned in 2 PCR blocks
  • -  Maximum. Heating Rate is 5 °C/s with temperature range of 0 to 100 °C
  • -  It has the capability to accommodate 96×0.2 ml or Double 48×0.2ml with moveable hot lid which can fit different sizes of tubes
  • -  It has the internal flash memory to store the 10000 files data for analysis
  • -  The connectivity between computer is via USB port and mini printer and can store the GLP data after every step to get reliable results
  • -  All the operations are controlled by a computer software system which instrument PCR protocols and also has in built 11 standard protocols
  • -  It has power of operation recovery option which helps in continuing the same command after a recovering from power cut
  • -  The user can access to his individual experimental data by setting a password and data management system
  • -  To satisfy the customers need it is installed with special feature like the user can add sample while the process is going on to encounter different variations
  • -  The user will be sent notifications via email about the process to alert when operation ends
Applications :

Used in Gene expression analysis, Pathogen detection, DNA methylation analysis, Genotyping and gene scanning, miRNA research etc.